Threaded flange connection technical requirement
Before the threaded flanges is installed, the appearance inspection must be carried out, the surface should be smooth, no defects such as sand, cracks, spots, burrs and other flanges can be reduced, and there should be no defects such as perforative scratches on the sealing surface.
When threaded flanges and pipe are assembled, flange vertical ruler is used to check the verticality of threaded flanges. When the design of parallel deviation dimensions of threaded flanges connection is not specified, it should not be greater than 1 and 5% of flange outer diameter, and not more than 2mm. When two threaded flanges are not parallel and exceed the required requirements, it must be withered and no multiple gaskets should be used for correction.
When the 1/2" ANSI B16.5 Stainless Steel Threaded Flange is welded to the pipe, the two sides shall be welded according to the standard, and the height of the welding foot shall comply with the regulations.
previous page:Slip on flange connection quality requirements
next pageDeterminants of quality standards for stainless steel socket pipe fitting